3651
0
310
Controller
RLC
331-409-2112
 
 
 
3
Six controller cables identified as B23, B25, B27, T66, I17, and U8 are not installed within the cable raceways and interfere with cabinet components. These should be reinstalled and rerouted through the correct raceways.
 
10/22/2009
 
 
 
0
 
 
 
 
View Edit
3652
0
310
Controller
RLC
 
 
 
 
3
Several controller base cables (X11, X12, Y10) are not following raceways into the cabinet structure. These should be routed to eliminate interference with other cabinet base wiring.
 
10/22/2009
 
 
 
0
 
 
 
 
View Edit
3653
0
310
Gearbox
RLC
 
 
 
 
3
Identified a leak at J2 pipe connection to gearbox oil cooler, possible o-ring failure or loose connection.
 
10/22/2009
 
 
 
0
 
 
 
 
View Edit
3654
0
310
Gearbox
RLC
 
 
 
 
3
Shows signs of leaks
 
10/22/2009
 
 
 
0
 
 
 
 
View Edit
3655
0
310
Generator
RLC
 
 
 
 
3
Termination cables are not marked from torque checks.
 
10/22/2009
 
 
 
0
 
 
 
 
View Edit
3656
0
310
Generator
RLC
 
 
 
 
3
Termination cables are not marked from torque checks.
 
10/22/2009
 
 
 
0
 
 
 
 
View Edit
3657
0
310
Nacelle
RLC
 
 
 
 
2
Identified a leak at K1 pipe connection to cooler, possible o-ring failure or loose connection.
 
10/22/2009
 
 
 
0
 
 
 
 
View Edit
3658
0
310
Nacelle
RLC
 
 
 
 
2
Identified Hydro level low when in standby condition. Requires attention by site personnel.
 
10/22/2009
 
 
 
0
 
 
 
 
View Edit
3659
0
310
Tower
RLC
 
 
 
 
1
Ladder has several bent rungs discovered during climb between lower and middle sections. Appears that something had 'dropped' onto them from above. The ladder safety system (LSS) cable rubs against the bottom and third doors. To correct this, the cable guides should be re-spaced to properly posistion the cable away from the doors.
 
10/22/2009
 
 
 
0
 
 
 
 
View Edit
3660
0
310
Tower
RLC
 
 
 
 
1
Identified three light fixtures with burned or malfunctioning bulbs during climb through middle and upper sections. These should be replaced and/or checked for operation.
 
10/22/2009
 
 
 
0
 
 
 
 
View Edit
3661
0
310
Tower
RLC
 
 
 
 
2
Did not conduct torque checks for this inspection however, was unable to find torque marks (identifiers for previous 10% torque check) on any inside tower structure bolts (lower, middle, upper, yaw deck). A full re-torque of the tower should be completed
 
10/22/2009
 
 
 
0
 
 
 
 
View Edit
3662
0
311
Blades (general)
RB
 
 
 
 
3
Identified some appearance of laminate separation on #1 blade. See mid section trailing edge.
 
10/23/2009
 
 
 
0
 
 
 
 
View Edit
3663
0
311
Brake
RB
 
 
 
 
3
Identified excessive brake dust coating the calipers. Brake pad material is within specifications.
 
10/23/2009
 
 
 
0
 
 
 
 
View Edit
3664
0
311
Controller
RB
 
 
 
 
3
A portion of the right half side of the controller touch screen is faded out and prohibits operator from read correctly. This may be systemic issue with control screens and should be further investigated.
 
10/23/2009
 
 
 
0
 
 
 
 
View Edit
3665
0
311
Down Tower
RB
 
 
 
 
3
Door filter is missing. Unable to determine last installation. Excessive down-tower dust is present.
 
10/23/2009
 
 
 
0
 
 
 
 
View Edit
3666
0
311
Gearbox
RB
 
 
 
 
2
Identified single loose bolt on shrink disc. See marking left on bolt head. Torque spec unknown.
 
10/23/2009
 
 
 
0
 
 
 
 
View Edit
3667
0
311
Gearbox
RB
 
 
 
 
2
Dog bone bushing showing wear and cracking. Should be replaced at next service interval.
 
10/23/2009
 
 
 
0
 
 
 
 
View Edit
3668
0
311
Generator
RB
 
 
 
 
3
Identified an excessive amount of (brush) material dusting on brush holders. Brush material is within specifications.
 
10/23/2009
 
 
 
0
 
 
 
 
View Edit
3669
0
311
Nacelle
RB
 
 
 
 
3
Excessive oil residue indicates previous/existing oil leaks. No other leaks identified in this inspection.
 
10/23/2009
 
 
 
0
 
 
 
 
View Edit
3670
0
311
Nacelle
RB
 
 
 
 
3
Left side anemometer is inoperable and appears to have a stuck/broken cup.
 