130
 
Bed Plate Info: (Cast or Weldment)
Nacelle
 
 
(Enter Data)
144
 
10/26/2009
Weldment.
 
4
318
PSmith-Rev1Wind1
131
 
General Cleanliness of Nacelle
Nacelle
 
 
 
144
Yes
10/26/2009
Nacelle is excessively dirty (some light trash, excess oil, absorbant materials) and requires cleaning.
 
4
318
PSmith-Rev1Wind1
132
 
Sound Proofing/Insulation
Nacelle
 
 
 
144
N/A
10/26/2009
 
 
4
318
PSmith-Rev1Wind1
133
 
Mounting Hardware
Nacelle
 
Required
 
144
Yes
10/26/2009
 
 
4
318
PSmith-Rev1Wind1
134
 
Safety Shields/Covers/Placards
Nacelle
 
 
 
144
Yes
10/26/2009
Missing pinch point placard on high speed guard cover
 
4
318
PSmith-Rev1Wind1
135
 
Oil Leaks
Nacelle
 
 
 
144
Yes
10/26/2009
Excessive oil residue indicates previous/existing oil leaks. No other leaks identified in this inspection.
 
4
318
PSmith-Rev1Wind1
136
 
Oil Absorbant or Drip Pans
Nacelle
 
 
 
144
Yes
10/26/2009
 
 
4
318
PSmith-Rev1Wind1
137
 
Hydraulic Station Oil Level
Nacelle
 
 
 
144
Yes
10/26/2009
Identified Hydro level low when in standby condition. Requires attention by site personnel.
 
3
318
PSmith-Rev1Wind1
138
 
Hydraulic ( Leaks, Condition)
Nacelle
 
 
 
144
Yes
10/26/2009
 
 
4
318
PSmith-Rev1Wind1
139
 
FAA Lighting (Record Fault Code)
Nacelle
 
 
 
144
Yes
10/26/2009
No fault codes. Lighting was off during inspection.
 
4
318
PSmith-Rev1Wind1
140
 
Anemometer/Wind Vane
Nacelle
 
 
 
144
Yes
10/26/2009
 
 
4
318
PSmith-Rev1Wind1
141
 
Nacelle Top Seals/Hatch Seals
Nacelle
 
 
 
144
Yes
10/26/2009
 
 
4
318
PSmith-Rev1Wind1
142
 
Tie Off Rail
Nacelle
 
 
 
144
Yes
10/26/2009
 
 
4
318
PSmith-Rev1Wind1
143
 
Overall Condition
Top Controller
 
 
 
144
Yes
10/26/2009
 
 
4
318
PSmith-Rev1Wind1
144
 
Mounting Hardware
Top Controller
 
 
 
144
Yes
10/26/2009
 
 
4
318
PSmith-Rev1Wind1
145
 
Insulation / Ventilation
Top Controller
 
 
 
144
Yes
10/26/2009
 
 
4
318
PSmith-Rev1Wind1
146
 
Cable Terminations
Top Controller
 
 
 
144
Yes
10/26/2009
Identified four cables that have missing/improperly installed ferrels on terminations. Requires attention.
 
4
318
PSmith-Rev1Wind1
147
 
Pannel Bottom In Place
Top Controller
 
 
 
144
Yes
10/26/2009
 
 
4
318
PSmith-Rev1Wind1
148
 
Brakes (general condition, pads)
Brake
 
 
 
144
Yes
10/26/2009
Identified excessive brake dust coating the calipers. Brake pad material shows evidence of uneven wear.
 
4
318
PSmith-Rev1Wind1
149
 
Shround Conditon
Brake
 
 
 
144
Yes
10/26/2009
 
 
4
318
PSmith-Rev1Wind1