107
|
Ladder / Safety Equipment
|
Tower
|
|
Required
|
Yes
|
22/10/2009
|
Ladder has several bent rungs discovered during climb between lower and middle sections. Appears that something had 'dropped' onto them from above. The ladder safety system (LSS) cable rubs against the bottom and third doors. To correct this, the cable guides should be re-spaced to properly posistion the cable away from the doors.
|
1
|
|
110
|
Tower Lighting / Wiring / Hardware
|
Tower
|
|
Required
|
Yes
|
22/10/2009
|
Identified three light fixtures with burned or malfunctioning bulbs during climb through middle and upper sections. These should be replaced and/or checked for operation.
|
1
|
|
142
|
Tie Off Rail
|
Nacelle
|
|
Required
|
Yes
|
26/10/2009
|
Tie-off rail is missing fastening (nuts/bolts) hardware on front section. Safety issue that should be immediately addressed.
|
1
|
|
150
|
Rotor Lock Condition
|
Brake
|
|
Required
|
N/A
|
26/10/2009
|
Identified difficulty in applying the rotor lock. Should be further investigated.
|
1
|
|
183
|
Rotor Hub Cleanliness
|
Hub & Rotor
|
|
Required
|
N/A
|
26/10/2009
|
Unable to enter hub for inspection. Rotor lock mechanism has been dismantled for service.
|
1
|
|
184
|
Delat Connection
|
Hub & Rotor
|
|
Required
|
N/A
|
26/10/2009
|
|
1
|
|
185
|
Pitch Gear Wear
|
Hub & Rotor
|
|
Required
|
N/A
|
26/10/2009
|
|
1
|
|
186
|
Pitch Bearings & Seals
|
Hub & Rotor
|
|
Required
|
N/A
|
26/10/2009
|
|
1
|
|
187
|
Pitch Rams ( Condition, Leaks)
|
Hub & Rotor
|
|
Required
|
N/A
|
26/10/2009
|
|
1
|
|
188
|
Proportional Valves ( condition, Leaks)
|
Hub & Rotor
|
|
Required
|
N/A
|
26/10/2009
|
|
1
|
|
189
|
Pitch Auto Luber
|
Hub & Rotor
|
|
Required
|
N/A
|
26/10/2009
|
|
1
|
|
89
|
Steps, Handrail, Door, Door Locks
|
Down Tower
|
|
Required
|
Yes
|
26/10/2009
|
Entrance stairs bottom step is loose. Safety issue that should be immediately addressed.
|
1
|
|
108
|
Tower (cracks, corrosion, bolts)
|
Tower
|
|
Required
|
Yes
|
26/10/2009
|
Identified excessive corrosion on base to mid flange bolts. See photos included in this report.
|
1
|
|
89
|
Steps, Handrail, Door, Door Locks
|
Down Tower
|
|
Required
|
Yes
|
26/10/2009
|
Handrail is missing on right side of stairs. Safety issue that should be immediately addressed.
|
1
|
|
111
|
Platform Doors
|
Tower
|
|
Required
|
Yes
|
26/10/2009
|
Platform door from middle to upper section has been removed and is missing. Safety issue that should be addressed immediately.
|
1
|
|
134
|
Safety Shields/Covers/Placards
|
Nacelle
|
|
Required
|
Yes
|
26/10/2009
|
Identified the emergency stop button on the main shaft is broken and inoperable. Safety issue-replace immediately.
|
1
|
|
150
|
Rotor Lock Condition
|
Brake
|
|
Required
|
Yes
|
26/10/2009
|
Identified that the right side rotor lock is bent. Unable to install. Safety issue that should be immediately addressed.
|
1
|
|
107
|
Ladder / Safety Equipment
|
Tower
|
|
Required
|
Yes
|
26/10/2009
|
LSS safety cable lower turnbuckle is damaged and should be replaced. See photo in report.
|
1
|
|
111
|
Platform Doors
|
Tower
|
|
Required
|
Yes
|
26/10/2009
|
LSS cable rub identified at upper platform door. Cable guide can be adjusted to eliminate this issue.
|
1
|
|
107
|
Ladder / Safety Equipment
|
Tower
|
|
Required
|
Yes
|
26/10/2009
|
The ladder safety system (LSS) cable rubs against the bottom and third doors. To correct this, the cable guides should be re-spaced to properly posistion the cable away from the doors.
|
1
|